Figure 1. Floor Plate.
AIR FILTER RESTRICTION SWITCH REPLACEMENT

Field Maintenance Manual For M400T And M400W
Page Navigation
  925    926    927    928    929  930  931    932    933    934    935  
img
.
TM 5-3805-292-23
0136
INSTALLATION
000136
N OT E
Install wires and electrical connectors as tagged during removal.
1. Install A/C pressure switch (Figure 2, Item 1) on machine and connect wiring harness (Figure 2, Item 2) to A/C
pressure switch.
2. Install floor plate (Figure 1, Item 3) in cab.
3. Install three bolts (Figure 1, Item 1) and washers (Figure 1, Item 2) on floor plate (Figure 1, Item 3).
END OF TASK
FOLLOW-ON TASKS
000136
1. Connect battery power (WP 0142).
2. Verify correct operation of machine (TM 5-3805-292-10).
END OF TASK
END OF WORK PACKAGE
0136-3/(4 blank)