TM 5-3805-292-23
0137
REMOVAL
000137
C AU T I O N
Failure to squeeze and hold locking clip before disconnecting connector may cause
damage to connector and air filter restriction switch.
1. Squeeze and hold locking clip (Figure 1, Item 2) and disconnect connector (Figure 1, Item 1) from air filter
restriction switch (Figure 1, Item 3).
2. Remove air filter restriction switch (Figure 1, Item 3) from intake air cleaner (Figure 1, Item 4) by turning coun-
terclockwise.
Figure 1. Air Filter Restriction Switch.
0137
END OF TASK
INSTALLATION
000137
WARN I N G
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
1. Apply sealing compound to threads on intake air cleaner (Figure 1, Item 4).
C AU T I O N
Do not over tighten air filter restriction switch. Failure to follow this caution may cause
damage to equipment.
2. Install air filter restriction switch (Figure 1, Item 3) on intake air cleaner (Figure 1, Item 4) by turning clockwise.
3. Connect wiring harness (Figure 1, Item 1) to air filter restriction switch (Figure 1, Item 3) and push locking clip
(Figure 1, Item 2) in place.
END OF TASK