TM 5-3805-298-23-1
0035
Table 1. Engine Cranks But Does Not Run - Continued.
035
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Engine Cranks But Does Not
Test Step 4. Inspect Air Cleaner Inlet
Run - Continued
Hose and Air Inlet Restriction Switch
and Hose.
1. Inspect air inlet restriction switch
Air Inlet Restriction Switch OK -
(Figure 4, Item 4) for cracks and
Proceed to step 2.
damage.
Air Inlet Restriction Switch Cracked
or Damaged - Replace air inlet
restriction switch (WP 0206).
Proceed to Test Step 12.
2. Inspect air inlet restriction switch
Air Inlet Restriction Switch Hose OK
hose (Figure 4, Item 5) for cracks,
- Proceed to step 3.
sharp bends, damage, or being
Air Inlet Restriction Switch Hose
collapsed or disconnected.
Disconnected - Connect air inlet
restriction switch hose (Figure 4,
Item 5) to air inlet restriction switch
(Figure 4, Item 4).
Proceed to Test Step 12.
Air Inlet Restriction Switch Hose
Collapsed or Has Sharp Bends -
Straighten or replace air inlet
restriction switch hose (Figure 4,
Item 5) (WP 0206).
Proceed to Test Step 12.
Air Inlet Restriction Switch Hose
Cracked or Damaged - Replace air
inlet restriction switch hose (Figure 4,
Item 5) (WP 0206).
Proceed to Test Step 12.
Air Cleaner Inlet Hose OK - Proceed
3. Inspect air cleaner inlet hose
to Test Step 5.
(Figure 4, Item 3) for cracks,
damage, and loose clamps
Air Cleaner Inlet Hose Cracked or
(Figure 4, Items 1 and 2).
Damaged - Replace air cleaner inlet
hose (Figure 4, Item 3) (WP 0204).
Proceed to Test Step 12.
Air Cleaner Inlet Hose Clamps
Loose - Tighten or replace air cleaner
outlet hose clamps (Figure 5, Items 1
and 2).
Proceed to Test Step 12.
0035-10