TM 5-3805-298-23-1
0038
Table 1. Engine Is Hard to Start When Cold - Continued.
038
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Engine Is Hard to Start
When Cold - Continued
ET will automatically disable glow plugs within 30
seconds.
9. While the glow plugs are activated,
Voltage 18 - 28 V - Select the Disable
Override button (Figure 6, Item 3) to de-
to test for voltage between glow
activate glow plugs.
plug buss bar (Figure 6, Item 1)
Select the Disconnect icon (Figure 6,
and machine ground.
Item 2).
Turn ignition switch and battery
disconnect switch to the OFF position
(TM 5-3805-298-10).
Proceed to Test Step 7.
Voltage Less Than 18 V - Select the
Disable Override button (Figure 6,
Item 3) to de-activate glow plugs.
Select the Disconnect icon (Figure 6,
Item 2).
Turn ignition switch and battery
disconnect switch to the OFF position
(TM 5-3805-298-10).
Proceed to step10.
0038-10