TM 5-3805-298-23-1
0052
Table 1. 168 Electrical System Voltage Diagnostic Codes - Continued.
052
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 7. Test Power Connection
168-2 Electrical System
at Fuse Module 1.
Voltage Erratic, Intermittent,
Voltage 18 to 26 V Proceed to Test
or Incorrect - Continued
Step 8.
(WP 0174), test for voltage
between fuse module 1 terminal 7
Voltage Less Than 18 V Proceed to
step 2.
Dirty, Corroded, or Loose Clean and
2. Inspect connection of fuse module
tighten as necessary.
for dirt, corrosion, and loose
Proceed to step 3.
connections.
No Problem Found Replace bus bar
between fuse module 2 and fuse
module 1 (WP 0263).
Proceed to Test Step 11.
Voltage 18 to 26 V Proceed to Test
Step 11.
(WP 0174), test for voltage
between fuse module 1 terminal 7
Voltage Less Than 18 V Replace bus
bar between fuse module 2 and fuse
module 1 (WP 0263).
Proceed to Test Step 11.
Test Step 8. Test Power Connection
at Fuse Module 1 Output.
Voltage 18 to 26 V Proceed to Test
(WP 0174), test for voltage
Step 9.
between fuse module 1 terminal
Voltage Less Than 18 V Proceed to
step 2.
ground.
2. Inspect connection of fuse module
Dirty, Corroded, or Loose Clean and
tighten as necessary.
Figure 44) for dirt, corrosion, and
Proceed to step 3.
loose connections.
No Problem Found Replace auxiliary
fuse in module 1 (WP 0263).
Proceed to Test Step 11.
Voltage 18 to 26 V Proceed to Test
(WP 0174), test for voltage
Step 11.
between fuse module 1
Voltage Less Than 18 V Replace
auxiliary fuse in module 1 (WP 0263).
and ground.
Proceed to Test Step 11.
0052-13