Table 1. 262 Five-Volt Sensor Power Supply Diagnostic Codes - Continued.
268 ENGINE CONTROL MODULE DIAGNOSTIC CODES

Field Maintenance Manual For 924H Wheel Loader -1 Page Navigation
  697    698    699    700    701  702  703    704    705    706    707  
img
. .
TM 5-3805-298-23-1
0058
Table 1. 262 Five-Volt Sensor Power Supply Diagnostic Codes - Continued.
058
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
8. Using digital multimeter
262-4 Five-Volt Sensor
Continuity - Replace engine control
(WP 0174), test for continuity
Power Supply Voltage Is
wiring harness (WP 0294).
between connector E-C4
Below Normal or the Voltage
Proceed to Test Step 4.
(WP 0012, Figure 10) terminal 48
Is Shorted Low - Continued
No Continuity - Replace engine ECM
and ground.
(WP 0265).
Proceed to Test Step 4.
Test Step 4. Verify Malfunction Is
Resolved.
1. Ensure all harness connectors are
connected.
2. Install right engine access panel
(WP 0348).
3. At MSD, check for active
Diagnostic Code 262-4 Five-Volt
diagnostic codes (WP 0008).
Sensor Power Supply Voltage Is
Below Normal Becomes Inactive -
Troubleshooting complete.
Diagnostic Code 262-4 Five-Volt
Sensor Power Supply Voltage Is
Below Normal Remains Active -
Repeat troubleshooting from the
beginning.
END OF WORK PACKAGE