Table 1. 2417 Start Aid Diagnostic Codes - Continued.
Figure 2. Ether Injection.

Field Maintenance Manual For 924H Wheel Loader -1 Page Navigation
  784    785    786    787    788  789  790    791    792    793    794  
img
.
TM 5-3805-298-23-1
0068
Table 1. 2417 Start Aid Diagnostic Codes - Continued.
068
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
6. Select Ether Injection (Figure 2,
2417-5 Ether Control
Item 1).
Solenoid Current Below
Normal - Continued
7. From the pop-up window
(Figure 2, Item 3), select the down
arrow (Figure 2, Item 4).
8. Select ON (Figure 2, Item 5) from
the drop down menu and select
OK (Figure 2, Item 6).
9. Select YES from pop-up window to
activate ether valve.
10. Using the MSD (WP 0008), check
Diagnostic Code 2417-5 Ether
for active diagnostic codes
Control Solenoid Current Below
Normal Is Active - Select the Disable
(Figure 2, Item 8).
Override button (Figure 4, Item 7) to de-
activate ether valve.
Select the Disconnect icon (Figure 4,
Item 2).
Proceed to Test Step 2.
Diagnostic Code 2417-5 Ether
Control Solenoid Current Below
Normal Is Not Active - Select the
Disable Override button (Figure 2,
Item 7) to de-activate ether valve.
Select the Disconnect icon (Figure 2,
Item 2).
Troubleshooting is complete.