TM 5-3805-298-23-1
0089
Table 1. 368 Auto-Shift Rocker Switch Diagnostic Codes - Continued.
089
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
Continuity - Proceed to Test Step 4.
368-4 Auto-Shift Switch
(WP 0174), test for continuity
Voltage Is Below Normal -
No Continuity - Proceed to step 5.
between connector HN-C6
Continued
and terminal 4.
Continuity - Proceed to Test Step 5.
(WP 0174), test for continuity
No Continuity - Proceed to step 6.
between connector HN-C6
and terminal 2.
Continuity - Proceed to Test Step 6.
(WP 0174), test for continuity
No Continuity - Proceed to Test Step 7.
between connector HN-C6
and terminal 2.
Test Step 4. Test for Shorted Lower
Cab Wiring Harness for Circuit Auto
and Manual.
1. Disconnect connector C-C1
Figure 66).
(WP 0174), test for continuity
harness (WP 0291).
between connector C-C1
Proceed to Test Step 11.
No Continuity - Replace main cab
and terminal 26.
wiring harness (WP 0293).
Proceed to Test Step 11.
Test Step 5. Test for Shorted Lower
Cab Wiring Harness for Circuit Auto
and Manual.
1. Disconnect connector C-C1
Figure 66).
(WP 0174), test for continuity
harness (WP 0291).
between connector C-C1
Proceed to Test Step 11.
No Continuity - Replace main cab
and terminal 7.
wiring harness (WP 0293).
Proceed to Test Step 11.
0089-9