TM 5-3805-298-23-1
0094
Table 1. 490 Implement Lockout Switch Diagnostic Codes - Continued.
094
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 2. Test for Faulty
490-4 Implement Lockout
Implement Lockout Switch.
Switch Voltage Is Below
Normal - Continued
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-298-10).
2. Remove console instrument panel
for access to wiring harness
connectors (WP 0264).
3. Disconnect connector C-C6
implement lockout switch
4. Push implement lockout switch to
OFF position (TM 5-3805-298-10).
Resistance 5.0 Ohms or Less -
(WP 0174), measure resistance
Replace implement lockout switch
between implement lockout switch
(WP 0264).
Proceed to Test Step 4.
and terminal 5.
Proceed to step 6.
6. Push implement lockout switch to
ON position (TM 5-3805-298-10).
Resistance 5.0 Ohms or Less -
(WP 0174), measure resistance
Replace implement lockout switch
between implement lockout switch
(WP 0264).
Proceed to Test Step 4.
and terminal 5.
Proceed to Test Step 3.
Test Step 3. Test for Shorted Lower
Cab Wiring Harness.
1. Remove left lower cab access
panels (WP 0347).
2. Remove transmission ECM cover
(WP 0266).
3. Disconnect connector C-C13
Transmission ECM J2.
(WP 0174), test for continuity
harness (WP 0291).
between connector C-C13
Proceed to Test Step 4.
and ground.
0094-6