TM 5-3805-298-23-1
0123
Table 1. Blackout Light Does Not Operate - Continued.
0123
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Continuity Proceed to Test Step 9.
Blackout Light Does Not
(WP 0174), test for continuity
Operate - Continued
No Continuity Replace blackout light
between connector LE-C22
Figure 44, Item 8).
and ground.
Proceed to Test Step 12.
Test Step 9. Test for Shorted Wiring
Harness.
1. Disconnect connector LE-C1
Figure 86).
Continuity Proceed to Test Step 10.
(WP 0174), test for continuity
No Continuity Replace front frame
between connector C-C10
wiring harness (WP 0301) and lighting
and ground.
Proceed to Test Step 12.
Test Step 10. Test for Shorted Main
Cab Wiring Harness.
1. Disconnect connector HN-C1
Figure 65).
Continuity Replace main cab wiring
(WP 0174), test for continuity
harness (WP 0293) and lighting fuse
between connector HN-C1
Proceed to Test Step 12.
and ground.
No Continuity Proceed to Test
Step 11.
Test Step 11. Test for Shorted Engine
Wiring Harness.
1. Remove right lower cab access
panels (WP 0347).
2. Disconnect connector EN-C2
Figure 13).
Continuity Replace engine wiring
(WP 0174), test for continuity
harness (WP 0299) and lighting fuse
between connector EN-C2
Proceed to Test Step 12.
and ground.
No Continuity Replace lower cab
wiring harness (WP 0291) and lighting
Proceed to Test Step 12.
0123-5