HYDRAULIC HOSE REPAIR INSTRUCTIONS CONTINUED
Installation
000173
NOTE
There are no serviceable seals on a quick disconnect/connect fitting. If leaks are present
fittings should be replaced.
Connect hose (Figure 1, Item 14) on machine. Push in until a click is heard. Once a click is heard firmly pull out on
hose to ensure connection was complete.
C. Split Flange Clamps EXAMPLE.
000173
Removal
000173
Remove four bolts (Figure 1, Item 16), washers (Figure 1, Item 17), two split flange clamps (Figure 1, Item 19),
hose (Figure 1, Item 15), and O-ring (Figure 1, Item 18) from machine. Discard O-ring.
Installation
000173
Install new O-ring (Figure 1, Item 18), hose (Figure 1, Item 15), two split flange clamps (Figure 1,
Item 19), four washers (Figure 1, Item 17), and bolts (Figure 1, Item 16) on machine.
Figure 1. Fittings and Clamps.