TM 5-2420-231-10
0006
FEL CONTROL LEVER - Continued
Table 1. FEL Control Lever Controls/Indicators.
KEY
CONTROL/INDICATOR
FUNCTION
1
Lift arms and bucket control lever
Controls lift arms and bucket.
Position A
FLOAT - Push lever forward past detent. Bucket can
follow level of ground without lever movement.
Position B
LOWER - Moves bucket down.
Position C
RAISE - Moves bucket up.
Position D
ROLL BACK - Rolls bucket back.
Position E
DUMP - Dumps bucket.
Position F
RETURN-TO-DIG - After bucket is dumped, move lever
to ROLLBACK and FLOAT. When bucket is at height
selected, pull lever back to HOLD.
Position G
NEUTRAL - Lift arms and bucket stop moving. When
released, lever will return to HOLD automatically.
Manually move lever from FLOAT to HOLD.