Table 1. Hard Start in Cold Temperatures (50F or Below) - Continued.
011
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Visually inspect voltage supply
Voltage Supply Cable Clean and
Hard Start in Cold
Tight - Proceed to step 5.
cable (Figure 5, Item 2) at heater
Temperatures (50F or
grid (Figure 5, Item 1) for being
Voltage Supply Cable Loose or
Below) - Continued
Corroded - Clean, tighten, or replace
clean and tight.
grid heater voltage supply cable
(WP 0160).
Proceed to Test Step 9.
5. Visually inspect ground cable
Ground Cable Clean and Tight -
Proceed to step 6.
(Figure 5, Item 3) at heater grid
(Figure 5, Item 1) for being clean
Ground Cable Loose or Corroded -
Clean, tighten, or replace grid heater
and tight.
ground cable (WP 0160).
Proceed to Test Step 9.
Figure 5. Heater Grid Assembly and Cables.