Figure 7. Cold Start Temperature Switch.
Table 1. Hard Start in Cold Temperatures (50F or Below) - Continued.

Tractor, Wheeled, Industrial Backhoe Loader Nsn 2420-01-532-3399
Page Navigation
  213    214    215    216    217  218  219    220    221    222    223  
img
. . .
TM 5-2420-231-23-1
0011
Table 1. Hard Start in Cold Temperatures (50F or Below) - Continued.
011
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Disconnect fuel shutoff solenoid
Hard Start in Cold
wiring harness connector (Figure
Temperatures (50F or
8, Item 2) from main chassis wiring
Below) - Continued
harness connector (Figure 8,
Item 1).
Figure 8. Fuel Shutoff Solenoid.
0011
3. Turn ignition switch to the on posi-
tion (TM 5-2420-231-10).
4. Using a digital multimeter, mea-
Voltage 10 to 14 Volts - Proceed to
sure voltage between main chas-
step 5.
sis wiring harness connector (WP
Voltage Less Than 10 Volts - Replace
0007, Figure 7) terminal 1 and
main chassis wiring harness (WP
machine ground. Voltage should
0154).
be 10 to 14 volts.
Proceed to Test Step 9.
5. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10), and dis-
connect batteries (WP 0157).