Table 1. Engine Runs Rough or Is Unstable - Continued.
012
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Engine Runs Rough or Is
Test Step 4. Inspect High-Pressure
Unstable - Continued
Fuel Tubes.
1. Install aspirate check valve
(Figure 5, Item 5) and clamp
(Figure 5, Item 4) on machine.
2. Install three clamps (Figure 5,
Items 3, 6, and 8) and two hoses
(Figure 5, Items 1 and 9) on aspi-
rate check valve (Figure 5, Item 5).
Figure 5. Aspirate Check Valve and Hoses.