Table 1. Alternator Does Not Charge or Alternator Charging Indicator Fault - Continued.
025
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 3. Inspect Battery and
Alternator Does Not Charge
Alternator Cables.
or Alternator Charging
Indicator Fault - Continued
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10).
2. Release two latches (Figure 5,
Item 2) and open battery cover
(Figure 5, Item 1).
3. Visually inspect negative battery
Battery Cable Connections OK -
cable (Figure 5, Item 3), positive
Proceed to step 4.
battery cable (Figure 5, Item 5),
Battery Cable Connections Loose/
and battery jumper cable
Dirty - Clean and tighten all
(Figure 5, Item 4) connections for
connections as required (WP 0158).
the following:
Proceed to Test Step 8.
Battery Cable Connections Frayed or
a. frays
Damaged - Replace battery cables
b. corrosion
(WP 0158).
c. loose connections
Proceed to Test Step 8.
d. damage
Figure 5. Battery Cables.