Table 1. Powershift Lever.
0053
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Powershift Lever
Always inspect wiring harness and connectors that are involved in the
circuit. Poor connections can often be the cause of a problem in an
electrical circuit. Verify that all connections in the circuit are clean and
secure, and that all connections are in good condition. If a problem with a
connection is found, correct the problem and verify this malfunction is
active before performing this procedure.
Perform an open or short circuit test at each wiring harness connection to
identify the correct wiring harness to replace.
Perform this test only if directed from another troubleshooting work
package.
Test Step 1. Test Powershift Lever
Input Circuits.
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
2. Remove instrument panel front
cover (WP 0174).
3. Connect powershift connector wir-
ing harness connector (WP 0007,
Figure 21) to powershift lever (WP
0007, Figure 114).
4. Place powershift lever in the N
position (TM 5-2420-231-10).
5. Remove front floor cover plate
(WP 0306).
6. Connect batteries (WP 0157) and
turn ignition switch to the on posi-
tion (TM 5-2420-231-10).
7. Using a digital multimeter, mea-
Voltage 10 to 14 Volts - Proceed to
sure voltage between powershift
Test Step 2.
connector wiring harness connec-
No Voltage - Proceed to step 8.
tor (WP 0007, Figure 20) terminal
C2 and machine ground. Monitor
and record voltage. There should
be no voltage present.
8. Using a digital multimeter, mea-
Voltage 10 to 14 Volts - Proceed to
sure voltage between powershift
Test Step 6.
connector wiring harness connec-
No Voltage - Replace transmission
tor (WP 0007, Figure 20) terminal
controller (WP 0168).
D2 and machine ground. Monitor
Connect powershift wiring harness
and record voltage. There should
connector (WP 0007, Figure 146) to
be no voltage present.
transmission (WP 0007, Figure 147).
Install front floor cover plate (WP 0306).
Proceed to Test Step 10.