TM 5-2420-231-23-1
0068
Table 1. Load Leveler Function Fails to Operate or Operates Improperly - Continued.
068
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8. Inspect rod (Figure 6, Item 1),
Rod, Retaining Hardware, and Clevis
Load Leveler Function Fails
OK - Proceed to step 9.
retaining hardware (Figure 6, Item
to Operate or Operates
3), and clevis (Figure 6, Item 2) for
Rod, Retaining Hardware, or Clevis
Improperly - Continued
Corroded or Damaged - Replace rod,
corrosion and damage.
retaining hardware, or clevis as
necessary (WP 0278).
Check and adjust load leveler control
adjustment as necessary (WP 0278).
Proceed to Test Step 3.
Rod Rotates Freely - Proceed to step
9. Manually rotate end of rod (Figure
10.
6, Item 4) counterclockwise and
Rod Binds When Rotated - Replace
release. Repeat several times to
verify rod rotates freely.
rod (WP 0278).
Check and adjust load leveler control
adjustment as necessary (WP 0278).
Proceed to Test Step 3.
Figure 6. Rod and Clevis.
0068