TM 5-2420-231-23-1
0068
Table 1. Load Leveler Function Fails to Operate or Operates Improperly - Continued.
068
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
10. Inspect cam and clevis (Figure 7,
Cam and Clevis OK - Proceed to step
Load Leveler Function Fails
Item 3) for corrosion and damage.
11.
to Operate or Operates
Cam or Clevis Corroded or Damaged
Improperly - Continued
- Replace cam and clevis (WP 0278).
Check and adjust load leveler control
adjustment as necessary (WP 0278).
Proceed to Test Step 3.
11. Inspect rod and clevis (Figure 7,
Rod and Clevis OK - Proceed to step
Item 4) for corrosion and damage.
12.
Rod or Clevis Corroded or Damaged
- Replace rod and clevis (WP 0278).
Check and adjust load leveler control
adjustment as necessary (WP 0278).
Proceed to Test Step 3.
12. Inspect cable (Figure 7, Item 2)
Cable and Retaining Hardware OK -
Check and adjust load leveler control
and retaining hardware (Figure 7,
Item 1) for corrosion and damage.
adjustment as necessary (WP 0278).
Proceed to Test Step 3.
Cable or Retaining Hardware
Corroded or Damaged - Replace
cable or retaining hardware as
necessary (WP 0278).
Check and adjust load leveler control
adjustment as necessary (WP 0278).
Proceed to Test Step 3.
Figure 7. Cam, Rod, Clevis, and Cable.
0068