TM 5-2420-231-23-2
0092
INSTALLATION CONTINUED
14. Install two washer hoses (Figure 48, Item 4), washer pump harness (Figure 48, Item 5), new locknut
(Figure 48, Item 1), clamp (Figure 48, Item 6), two washers (Figure 48, Item 2), and bolt (Figure 48, Item 3) on
coolant reservoir mount (Figure 48, Item 7).
Figure 48. Side Washer Pump Wiring Harness Clamp.
0092
NOTE
The procedure for washer pump connections is identical for left-hand and right-hand
washer pump connections. Left-hand washer pump connections are shown in this
procedure.
Install hoses and wires as tagged and marked during removal.
15. Connect washer hose (Figure 49, Item 1) and washer pump wiring harness (Figure 49, Item 3) to washer pump
(Figure 49, Item 2).
16. Repeat step 15 for right-side washer pump.