4
TM 5-2420-231-23-3
FIELD MAINTENANCE
-
BLOWER ASSEMBLY REPLACEMENT
0
348
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
References
Tools and Special Tools
Tool Kit, General Mechanic's
0
0
0
Materials/Parts
0
Cleaning Compound, Solvent, Type III
Equipment Conditions
0
0
0
Estimated Time to Complete
0
5.7 hr
0
0
Personnel Required
Two
0
REMOVAL
0348
1. With assistance, remove evaporator (Figure 1, Item 1) from blower housing (Figure 1, Item 3).
2. With assistance, remove heat exchanger (Figure 1, Item 2) from blower housing (Figure 1, Item 3).
3. With assistance, remove blower motor (Figure 1, Item 4) from blower housing (Figure 1, Item 3).
Figure 1. Blower Housing.
0348