TM 5-3805-255-14
0037
CLEANING, INSPECTION
00037
1. Clean and inspect all parts IAW General Maintenance Instructions (WP 0019).
2. Inspect thermostats for deterioration, damage, and cracks and burrs, and replace if necessary.
END OF TASK
INSTALLATION
00037
1. Install two new seals (Figure 1, Item 5) in thermostat housing (Figure 1, Item 14) with lip of seals facing down.
Surface of seal must be flush with housing inner surface and parallel with housing gasket surface.
2. Install two thermostats (Figure 1, Item 6) in thermostat housing (Figure 1, Item 14).
3. Install new gasket (Figure 1, Item 7) on thermostat housing (Figure 1, Item 14).
4. Install thermostat housing (Figure 1, Item 14), two lockwashers (Figure 1, Item 2), nuts (Figure 1, Item 8), and
bolts (Figure 1, Item 1) on manifold assembly (Figure 1, Item 9).
5. Install bolt (Figure 1, Item 13) and washer (Figure 1, Item 12) on thermostat housing (Figure 1, Item 14).
6. Install three new lockwashers (Figure 1, Item 12), bolts (Figure 1, Item 13), and nuts (Figure 1, Item 8) on
thermostat housing (Figure 1, Item 14) and manifold assembly (Figure 1, Item 9).
7. Install lower hose (Figure 1, Item 10) and clamp (Figure 1, Item 11) on thermostat housing (Figure 1, Item 14).
8. Install upper hose (Figure 1, Item 3) and clamp (Figure 1, Item 4) on thermostat housing (Figure 1, Item 14).
END OF TASK
END OF WORK PACKAGE
0037-3/(4 blank)