TM 5-3805-258-24-1When RequiredCLEANING AIR CLEANER ELEMENTSWARNINGIf NBC exposure is suspected, all air filter mediashould be handled by personnel wearing pro-tective equipment. Consult your unit NBC Offi-cer or NBC NCO for appropriate handling or dis-posal instructions.WARNINGWhen using pressure air wear a protectiveface shield and protective clothing. Themaximum air pressure must be below 205kPa (30 psi) for cleaning purposes.CAUTIONDo not clean any elements by bumping ortapping.Do not use elements with damagedpleats, gaskets or seals.Have spare elements on hand to usewhile cleaning used elements.Pressure Air — 205 kPa (30 psi)Maximum1. Direct the air inside the element alongthe length of the pleats.2. Direct the air outside the elementalong the length of the pleats. Direct the airinside the element along the length of thepleats. Inspect the element.Water — 280 kPa (40 psi) Maximum1. Direct the water inside the elementalong the length of the pleats.2. Direct the water outside the elementalong the length of the pleats, Rinse and airdry thoroughly Inspect the element.1-21