TM 5-3805-262-10
3-5. TROUBLESHOOTING TABLE (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
12. BATTERIES FAIL TO MAINTAIN CHARGE (VOLTMETER INDICATES LOW) (CONT)
Step 2.
Check for loose wire connection
a. If wire connection is loose
organizational maintenance.
at rear of alternator.
at rear of alternator, notify
b. If alternator connections are okay, go to step 3 below.
Step 3.
Open radiator grille at rear
Check for loose battery ca-
bles or dirty connections
at battery terminals.
a. If battery cables are
loose, dirty or corrod-
ed, notify organization-
al maintenance.
b. If battery cables are
not loose and connec-
tions are not dirty or
corroded, notify organi-
zational maintenance.
of loader.
13. BATTERIES REQUIRE FREQUENT FILLING
If batteries require frequent filling, notify
14. TRANSMISSION OVERHEATS (CONV TEMP GAGE INDICATES
organizational maintenance.
IN RED ZONE)
Step 1.
Place transmission control lever in lower speed range.
Check if CONV TEMP gage pointer remains in red zone.
a. If pointer remains in red zone, go to step 2 below.
b. If pointer goes into green zone, continue operation of loader.
3-24