TM 5-3805-262-103-5. TROUBLESHOOTING TABLE (CONT)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION12. BATTERIES FAIL TO MAINTAIN CHARGE (VOLTMETER INDICATES LOW) (CONT)Step 2.Check for loose wire connectiona. If wire connection is looseorganizational maintenance.at rear of alternator.at rear of alternator, notifyb. If alternator connections are okay, go to step 3 below.Step 3.Open radiator grille at rearCheck for loose battery ca-bles or dirty connectionsat battery terminals.a. If battery cables areloose, dirty or corrod-ed, notify organization-al maintenance.b. If battery cables arenot loose and connec-tions are not dirty orcorroded, notify organi-zational maintenance.of loader.13. BATTERIES REQUIRE FREQUENT FILLINGIf batteries require frequent filling, notify14. TRANSMISSION OVERHEATS (CONV TEMP GAGE INDICATESorganizational maintenance.IN RED ZONE)Step 1.Place transmission control lever in lower speed range.Check if CONV TEMP gage pointer remains in red zone.a. If pointer remains in red zone, go to step 2 below.b. If pointer goes into green zone, continue operation of loader.3-24