TM 5-3805-262-2012-1. SIGNALING DEVICES MAINTENANCE (CONT) a. Back-up Alarm and Switch (cont).INSTALLATION (SHEET 2 OF 2)(4) At rear of loader, position back-up alarm (10) and install two washers(9), capscrews (8), and washers (7).( 5 ) C o n n e ct( 6 ) I n s t a l l( 7 ) C o n n e c t( 8)I n s t a l l( 9 ) C o n n e c t( 1 0 ) I n s t a l lwire (6) terminal to one capscrew (8).and tighten two lock washers (5) and nuts (4).wiring harness black-red wire terminal (3) to back-up alarm (10).and tighten nut (2).wire (6) terminal to back-alarm (10).a n d t i g h t e n n u t ( l ) .( 1 1 ) C l o s e a n d l o c k r a d i a t o r g r i l l e.(12) Start engine and place transmission control lever in reverse (R) posi-tion. Check that back-up alarm sounds. Turn off engine. If back-up alarmdoes not sound, refer to troubleshooting (page 3-196).12-6