TM 5-3805-262-20
12-1. SIGNALING DEVICES MAINTENANCE (CONT)
a. Back-up Alarm and Switch (cont).
INSTALLATION (SHEET 2 OF 2)
(4) At rear of loader, position back-up alarm (10) and install two washers
(9), capscrews (8), and washers (7).
( 5 ) C o n n e ct
( 6 ) I n s t a l l
( 7 ) C o n n e c t
( 8)
I n s t a l l
( 9 ) C o n n e c t
( 1 0 ) I n s t a l l
wire (6) terminal to one capscrew (8).
and tighten two lock washers (5) and nuts (4).
wiring harness black-red wire terminal (3) to back-up alarm (10).
and tighten nut (2).
wire (6) terminal to back-alarm (10).
a n d t i g h t e n n u t ( l ) .
( 1 1 ) C l o s e a n d l o c k r a d i a t o r g r i l l e.
(12) Start engine and place transmission control lever in reverse (R) posi-
tion. Check that back-up alarm sounds. Turn off engine. If back-up alarm
does not sound, refer to troubleshooting (page 3-196).
12-6