TM 5-3805-262-20
INSTALLATION (SHEET 2 OF 2)
(5)
(6)
(7)
(8)
( 9)
(10)
Position bushing (10) and washer (9) on threaded stud of housing (8).
Position housing (8) by guiding terminal (5) end of wire through mounting
hole in bracket.
Slide lock washer (7) and lock nut (6) over terminal (5) end of wire,
install on housing (8), and tighten using open end wrench.
Connect flood light terminal (5) to wiring harness green wire terminal
(4) by grasping both in fingers, alining, and firmly pushing them
together. Connect driving light terminal (5) to wiring harness pink wire
t e r m i n a l ( 4 ).
Connect terminals (3) to lamp (2) terminals by grasping in your fingers,
alining, then firmly pushing onto lamp terminals.
Position lamp (2) in housing (8) and push retainer (1) over lamp. Push
retainer tangs into housing cut outs using screwdriver as necessary.
5-97