SPECIFIC GRAVITY CHECK (SHEET 2 OF 2)
(h)
If corrected specific gravity of all cells is 1.225 to 1.260, and the
difference between highest and lowest value is less than 0.050, the
battery is charged and okay.
I f c o r r e c t e d s p e c i f i c g r a v i t y o f a n y c e ll
is less than 1.225, or if difference between highest and lowest value
is more than 0.050, charge battery (page 5-146) and recheck specific
g r a v i t y . I f a n y c e l l i s s t i l l l e s s t h a n 1 . 2 2 5 , o r i f d i f f e r e n c e b e -
tween highest and lowest value is still more than 0.050, battery is
defective. Replace battery (page 5-148).
( i )
Install battery cell caps by turning clockwise .
( j )
C l o s e r a d i a t o r g r i l l e.
5-145