TM 5-3805-262-20
INSPECTION
(1)
( 2 )
( 3 )
(4)
(5)
(6)
(7)
Inspect cover (18) for cracks, splits, elongated mounting holes, or other
damage. Replace if necessary.
Inspect resistor (17) for cracks, chips, or loose or corroded terminals;
replace if any of these conditions are seen.
C h e c k s e a l ( 1 2 ) f o r d e t e r i o r a t i o n ; r e p l a c e i f d e t e r i o r a t e d,
Check defroster (11) for cracks or dents. Replace if cracked or dented.
Inspect defroster wire leads for cracked or broken insulation or broken
wire strands at connection to terminals. Repair cracked or broken insula-
tion by applying insulation tape to area. If broken wire strands are
seen, cut wire as close to terminals as possible. Strip 1/4 inch insula-
tion from end of wire taking care not to cut through wire then crimp new
terminals securely onto wire. Connect multimeter between terminals and
check for continuity. Replace defroster if continuity not obtained on
multimeter.
Inspect wiring harness terminal (6) wire for cracked or broken insulation
or broken wire strands at connection to terminal. Repair cracked or brok -
en insulation by applying insulation tape to area. If broken wire strands
are seen, cut wire as close to terminal as possible. Strip 1/4 inch
insulation from end of wire taking care not to cut through wire then
crimp new terminal securely onto wire.
Inspect wire lead (7) for cracked or broken insulation or broken wire
strands at connection to terminals. Repair cracked or broken insulation
by applying insulation tape to area. If broken wire strands are seen, re-
place wire lead.
Inspect remaining parts for cracks, breaks, distortion, bent condition,
or damaged or stripped threads; replace as necessary.
10-55