TM 5-3805-262-20
10-7. CAB DEFROSTER MAINTENANCE (CONT)
b. Defroster Switch and Circuit Breaker (cont).
INSTALLATION (SHEET 1 OF 2)
(1) Inspect wire lead (4) for cracked or broken insulation or broken wire
strands at connection to terminals. Repair cracked or broken insulation
by applying insulation tape to area.
If broken wire strands are seen, re-
place wire lead.
(2) Inspect wiring harness spade terminals (5, 6, and 7) wire for cracked or
broken insulation or broken wire strands at connection to spade terminal.
Repair cracked or broken insulation by applying insulation tape to area.
If broken wire strands are seen,
cut wire as close to spade terminal as
possible. Strip 1/4 inch insulation from end of wire taking care not to
cut through wire then crimp new spade terminal securely onto wire.
(3) Install double spade terminal (8) on circuit breaker (13) terminal by
grasping terminal (8) with your fingers and firmly pushing it onto
c i r c u i t b r e a k e r t e r m i n a l.
10-60