TM 5-3805-262-20
INSTALLATION
(1)
(2)
(3)
(4)
( 5)
(6)
(7)
(8)
( 9)
Inspect wiring harness spade terminal (4) wire for cracked or broken in-
sulation or broken wire strands at connection to spade terminal. Repair
cracked or broken insulation by applying insulation tape to area. If
broken wire strands are seen, cut wire as close to spade terminal as pos-
sible. Cut 1/4 inch insulation from end of wire taking care not to cut
through wire then crimp new spade terminal securely onto wire.
Position dome light switch (9) on cover.
Install and tighten two screws (8) to secure dome light switch (9).
Position lamp body (7) on cover.
Install and tighten four screws (6) to secure lamp body (7) to cover .
Connect lamp spade terminal (5) to dome light switch (9) terminal by
grasping terminal (5) with your fingers and firmly pushing onto switch
t e r m i n a l.
I f n e c e s s a r y, i n s t a l l b u l b ( 3 ).
Position lens (2) and secure by installing and tightening two screws (1).
I n s t a l l d e f r o s t e r m o t o r ( s t e p s ( 6 ) t h r o u g h ( 1 1 ) , p a g e 1 0 - 5 7 ) a n d c o n n e c t
battery ground cable (page 5-151).
10-69