TM 5-3805-290-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
INCLUDING LUBRICATION INSTRUCTIONS - CONTINUED
0012 00
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
PROCEDURE
CAPABLE IF:
NO.
INTERVAL
HOURS
a. Maintain oil level between LOW
35
After
0.2 Hour Transmission
Oil Level
mark and HIGH mark on transmis-
(Con't)
(HOT
sion oil level sight gage.
CHECK)
b.Wipe area clean around dipstick and
filler tube with a rag (Item 13, WP
WARN I N G
Filler tube is under pressure. Open tube slowly. Failure
to follow this warning may result in injury to personnel.
c. Turn T-handle counterclockwise (to
the left) to remove dipstick from
filler tube.
d.Wipe dipstick clean, then reinsert
into filler tube until fully seated.
Remove dipstick and take reading.
e. Maintain level between cross-
hatched area on FULL-WARM OIL-
NEUTRAL AT LI side of dipstick.
f. If level is low, add lubricating oil
through filler tube opening until
level is correct. Refer to KEY at end
of this work package for correct
grade of oil for expected tempera-
ture range.
g.Reinstall dipstick.
0012 00-24