TM 5-3805-290-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
INCLUDING LUBRICATION INSTRUCTIONS - CONTINUED
0012 00
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
53
After
Ether Starting
Aid System
WARN I N G
Ether fuel is extremely flammable and toxic. DO NOT
smoke and make sure you are in a well-ventilated area
away from heat, open flames, or sparks. Wear eye pro-
tection. Avoid contact with skin and eyes and avoid
breathing ether fumes. If fluid enters or fumes irritate
the eyes, wash immediately with large quantities of clean
water for 15 minutes. Seek medical attention immedi-
ately if ether is inhaled or causes eye irritation. Failure to
follow this warning may cause serious injury or death to
personnel.
N OT E
Ether canister needs to be installed when starting below
40F (4C).
a. Ensure ether canister is present and Ether canister is missing or
loose.
securely installed.
b.If canister is not installed, ensure cap
c. Leave right-side engine enclosure
access door open.
a. Open fan housing access door.
54
After
Fan Housing
b.Check for leaks and damage to fan Damage that would impair
operation. Class III leaks are
housing and fan motor.
c. Inspect radiator core for debris and evident.
dust. If necessary, use high pressure
water to remove debris and dust
from radiator core.
d.Open toolbox. Ensure lubricating
gun is clean and in good condition
Close toolbox.
e. Close fan housing access door.
f. Close right-side engine enclosure
access door, then close left-side
access door.
0012 00-41