TM 5-3805-290-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
INCLUDING LUBRICATION INSTRUCTIONS - CONTINUED
0012 00
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
62
After
Platform and
(Con't)
Top of
Machine
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III
is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes
and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames
and other sources of ignition. Failure to follow this
warning may result in injury or death to personnel.
(2) Ensure filler opening screen is
free of debris and clean. If not
clean, reach in with your fingers
and pull out screen. Clean
screen with solvent cleaning
compound, dry thoroughly, and
reinstall.
427-B0586A
(3) Add oil (Item 9, 10, 11, or 12,
opening until oil level is visible
in sight gage.
(4) To install filler cap, turn cap
one-quarter turn clockwise (to
the right) and lower tab.
0012 00-46