TM 5-3805-290-23-2
ELECTRICAL GENERAL MAINTENANCE INSTRUCTIONS - CONTINUED
0022 00
N OT E
Use electrically conductive grease on unprotected (exposed to weather) electrical connectors before
connections are made.
Use electrical insulating varnish on all electrical connections mounted outside of machine which are
exposed to harsh weather and/or road spray.
0022 00
CLEANING AND INSPECTION
CAU T I ON
Washing electrical wires with solvent cleaning compound or mineral spirits will cause serious damage or
destroy the material.
1.
Wash electrical wires with a mild solution of detergent and water and wipe dry.
2.
Inspect electrical wires and repair if necessary as specified in accompanying diagrams.
3.
Inspect all other components in accordance with WP 0023 00.
0022 00-2