FLASH PROGRAMMING
ENGINE ELECTRONIC CONTROL MODULE (ECM) REPLACEMENT

Manual 2 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  177    178    179    180    181  182  183    184    185    186    187  
img
TM 5-3805-290-23-2
MACHINE ELECTRONIC CONTROL MODULE (ECM) REPLACEMENT - CONTINUED
0052 00
COPY CONFIGURATION (PROGRAM ECM)
0052 00
1.
Highlight the ECM, then click "OK".
2.
Ensure the correct ECM is highlighted. Double click "Product ID" and change it to the product ID listed on the data
plate.
3.
ET will disconnect and then reconnect. Highlight the ECM again, then click "OK".
4.
Ensure the correct ECM is highlighted. Select "Copy Configuration" from the "Service" menu, then select "ECM
Replacement" from the sub-menu.
5.
Highlight configuration file saved earlier and double-click to open. "The current ECM Replacement data came from..."
dialogue box opens. Select "OK".
6.
Select "Program ECM" push-button, then highlight the ECM to be programmed and click "OK".
7.
Read the "Warning! This configuration is for the control..." message and verify that the appropriate description appears,
then select "Yes" to "Program the ECM".
N OT E
As the data are loading to the ECM, the "Please wait..." message displays. Then the "Loading data to
ECM..." progress bar is displayed. You may cancel the process at any time by pressing the "Cancel"
push-button. The "Are you sure..." dialogue box is displayed. Press "Yes" to cancel loading the data or
"No" not to cancel.
8.
If the "Programming parameter cannot be programmed..." message appears, select "OK".
9.
Close the "Programming complete..." dialogue box by selecting "OK".
10.
The "Programming parameter cannot be programmed..." message will reappear. Select the "Print" push-button. Then
select "OK".
11.
Start engine. Run until operating temperature is reached and verify proper operation of all components (TM 5-3805-
290-10). Check for active diagnostic codes by selecting "Active Diagnostic Codes" from the "Diagnostics" menu (WP
0005 00).
12.
Disconnect ET (WP 0006 00).
END OF WORK PACKAGE
0052 00-9/(0052 00-10 Blank)


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.