RELAY REMOVAL - CONTINUED
19.
20.
Perform steps 2 and 3 to remove defroster relay (45).
21.
Remove two nuts (46) and four wiring harness connections (47) from relay (48).
22.
Remove two bolts (49) and relay (48) from machine.