RELAY REMOVAL - CONTINUED
RELAY INSTALLATION - CONTINUED

Manual 2 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  193    194    195    196    197  198  199    200    201    202    203  
img
.
TM 5-3805-290-23-2
FUSE, RELAY, AND CIRCUIT BREAKER REPLACEMENT - CONTINUED
0054 00
RELAY INSTALLATION
N OT E
Table 2 will direct you to the proper steps and callout to install each specific component.
Table 2. Relay Description Chart - Installation.
RPSTL
Component Name
Refer to Step(s)
Callout
Figure
Fuel pump relay
18 thru 20
8
62
Ether starting aid relay
21
11
62
Lift pump relay
21
12
62
Ride control relay
22
13
59
Starter relay
14 thru 17
16
62
Service light relay (Blackout)
12 and 13
20
42
Worklight relay (Blackout)
12 and 13
21
42
Horn relay
12 and 13
22
42
Back up alarm relay
12 and 13
23
42
(Blackout)
12 and 13
24
42
Turnlamp flasher relay
(Blackout)
Condenser relay
10 and 11
29
165
Secondary steering relay
7 thru 9
34
57
Stop lamp relay
5 and 6
42
43
Ride control relay (fuse box)
5 and 6
43
59
Secondary steering relay
5 and 6
44
43
(fuse box)
Defroster relay
3 and 4
45
117 and
125
Main power relay
1, 2, and 4
48
43
1.
Install relay (48) and two bolts (49) on machine.
2.
Install four wiring harness connections (47) and two nuts (46) on relay (48).
3.
Perform steps 18 and 19 to install defroster relay (45).
4.
Position and mount fuse box on machine (WP 0175 00).