TM 5-3805-290-23-2
FUSE, RELAY, AND CIRCUIT BREAKER REPLACEMENT - CONTINUED
0054 00
CIRCUIT BREAKER REMOVAL
0054 00
N OT E
Refer to Figure 68 in RPSTL for all circuit breakers.
Table 3. Circuit Breaker Description Chart - Removal.
Component Name
Callout
Lamp circuit breaker
51
Auxiliary circuit breaker
59
Main circuit breaker
60
61
1.
Pull back two covers (50) on circuit breaker (51).
2.
Remove two nuts (52), bolts (53), washers (54), and wiring connections (55) from circuit breaker (51).
3.
Remove two nuts (56), bolts (57), washers (58), and circuit breaker (51) from machine.
4.
Perform step 1 for circuit breakers (59, 60, and 61).
427-B1956
0054 00-13