• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
RELAY INSTALLATION - CONTINUED
CIRCUIT BREAKER INSTALLATION

Manual 2 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  197    198    199    200    201  202  203    204    205    206    207  
img
TM 5-3805-290-23-2
FUSE, RELAY, AND CIRCUIT BREAKER REPLACEMENT - CONTINUED
0054 00
CIRCUIT BREAKER REMOVAL
0054 00
N OT E
Refer to Figure 68 in RPSTL for all circuit breakers.
Table 3. Circuit Breaker Description Chart - Removal.
Component Name
Callout
Lamp circuit breaker
51
Auxiliary circuit breaker
59
Main circuit breaker
60
Alternator circuit breaker
61
1.
Pull back two covers (50) on circuit breaker (51).
2.
Remove two nuts (52), bolts (53), washers (54), and wiring connections (55) from circuit breaker (51).
3.
Remove two nuts (56), bolts (57), washers (58), and circuit breaker (51) from machine.
4.
Perform step 1 for circuit breakers (59, 60, and 61).
427-B1956
0054 00-13