TM 5-3805-290-23-2
NATO SLAVE RECEPTACLE REPLACEMENT - CONTINUED
0080 00
REMOVAL
1.
Remove top bolt (1), washer (2), and disconnect cable (3) from NATO slave receptacle (4).
2.
Remove bolt (5), washer (6), and disconnect cable (7) from machine.
427-B1836
3.
Remove four bolts (8), eight washers (9), four nuts
(10), cover (11), and tether (12) from NATO slave
receptacle (4).
4.
Remove NATO slave receptacle (4) and plate (13)
from battery box (14).
427-B0817
0080 00-2