TM 5-3805-290-23-2
IMPLEMENT RELIEF VALVE REPLACEMENT - CONTINUED
0125 00
INSTALLATION - CONTINUED
4.
Install three new O-rings (20) on pressure reducing
valve (18).
5.
Install four new back-up O-rings (19) on pressure
reducing valve (18).
427-B1031
6.
Install pressure reducing valve (18) in implement
relief valve block (2). Tighten pressure reducing valve
to 27 2 lb-ft (37 3 Nm).
427-B1030
0125 00-5