AIR CONDITIONING/HEATER BLOWER MOTOR REPLACEMENT - CONTINUED
AIR CONDITIONING/HEATER BLOWER MOTOR REPLACEMENT - CONTINUED

Manual 2 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  711    712    713    714    715  716  717    718    719    720    721  
img
TM 5-3805-290-23-2
AIR CONDITIONING/HEATER BLOWER MOTOR REPLACEMENT - CONTINUED
0143 00
REMOVAL - CONTINUED
9.
Remove bolt (16) and washer (17) from motor mount.
10.
Remove nut (18) and washer (19) from motor mount.
11.
Disconnect AC wiring harness (20) from fan motor
(23).
12.
Disconnect AC wiring harness (20) from resistor (22).
427-B0741
13.
Disconnect AC wiring harness (20) from resistor (22).
14.
Remove bolt (24) and washer (25) from motor mount.
15.
Remove nut (26) and washer (27) from motor mount.
16.
Remove blower assembly (28) from case assembly (3).
17.
Disconnect AC wiring harness (20) from thermostat switch (29).
18.
Remove and discard two tiedown straps (31) from AC wiring harness (20).
19.
Remove AC wiring harness (20) from clip (30).
20.
Remove AC wiring harness (20) from grommet (32).
21.
Remove grommet (32) from case assembly (3).
22.
Disconnect AC wiring harness (20) from cab harness (33) and remove from machine.
427-B0742
0143 00-4