GEAR MOTOR HYDRAULIC FAN REPLACEMENT - CONTINUED
PILOT OPERATED CONTROL (JOY STICK) AND HYDRAULIC LOCKOUT VALVE REPLACEMENT

Manual 2 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  1070    1071    1072    1073    1074  1075  1076    1077    1078    1079    1080  
img
TM 5-3805-290-23-2
GEAR MOTOR HYDRAULIC FAN REPLACEMENT - CONTINUED
0187 00
INSTALLATION - CONTINUED
6.
Lubricate three new O-rings (6) with a thin coat of
clean oil and install in hose assemblies (4).
7.
Connect three hose assemblies (4) to fan motor (5).
427-B0761
8.
Position fan guard (3) and install 20 washers (2) and
fan guard bolts (1) on fan guard.
427-B0760
9.
Check hydraulic fluid level (TM 5-3805-290-10).
WAR N I N G
After replacing hydraulic component, make sure all personnel stand clear of machine during start up.
If hydraulic fluid escapes under pressure, it can penetrate the skin causing injury to personnel.
10.
Run engine until normal operating temperature is reached (TM 5-3805-290-10).
11.
Shut down engine (TM 5-3805-290-10).
12.
Check for hydraulic leaks.
END OF WORK PACKAGE
0187 00-9/(0187 00-10 Blank)