Table 7. J1 Connector (Implement ECM).
ELECTRO-HYDRAULIC SYSTEM - CONTINUED

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  279    280    281    282    283  284  285    286    287    288    289  
img
TM 5-3805-291-23-1
THEORY OF OPERATION - CONTINUED
0003 00
ELECTRO-HYDRAULIC SYSTEM - CONTINUED
Table 7. J1 Connector (Implement ECM) - Continued.
Function
Type
No.(1)
60
Auxiliary Solenoid
Output
Return
61
Anti-Drift Lower Solenoid
Output
62
Anti-Drift Dump Solenoid
Output
70
Battery
Power
(1)
Connector contacts that are not listed are not used.
Table 8. J2 Connector (Implement ECM).
Function
Type
No.(1)
2
Pilot Hydraulic Supply Solenoid
4
Pilot Solenoid Return
Output Return
8
Solenoid Return
24
Lift Lever Position Sensor
Input (PWM)
25
Tilt Lever Position Sensor
Input (PWM)
26
Third Lever Position Sensor
Input (PWM)
30
Auxiliary Function Continued Flow (N/O)
Input
31
Auxiliary Function Continued Flow (N/C)
Input
32
Rotary Lift Linkage Position Sensor
Input (PWM)
33
Rotary Tilt Linkage Position Sensor
Input (PWM)
67
Machine CAN Data Link
Input/Output
68
Machine CAN Data Link
Input/Output
(1)
Connector contacts that are not listed are not used.