TM 5-3805-291-23-1
ELECTRICAL SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0013 00
ETHER INJECTION SYSTEM TEST - CONTINUED
427-C0683
427-C0682
2.
Check for active diagnostic codes.
N OT E
Remove ether canister before you perform this procedure.
a.
b.
Place battery disconnect switch in ON position (TM 5-3805-291-10).
c.
Proceed to Diagnostic Overrides screen on ET.
d.
Activate ether injection system. System will activate for 10 seconds.
e.
Monitor Active Diagnostic Code screen on ET. Check and record any active diagnostic codes.
N OT E
Wait at least 30 seconds for diagnostic codes to become active.
f.
Look for an FMI 05 diagnostic code or an FMI 06 diagnostic code.
Expected Results. No diagnostic codes are active.
g.
(1)
If results are OK, neither diagnostic code is active. Problem may have been caused by a poor electrical
connection. Carefully reinspect connectors and wiring. Refer to Electrical Connector Inspection (WP
(2)
If results are not OK, an FMI 06 code is active at this time. Proceed to step 3.
(3)
If results are not OK, an FMI 05 code is active at this time. Proceed to step 4.
0013 00-48