FUEL FILTER DIFFERENTIAL PRESSURE SWITCH CIRCUIT TEST
FUEL FILTER DIFFERENTIAL PRESSURE SWITCH CIRCUIT TEST - CONTINUED

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  866    867    868    869    870  871  872    873    874    875    876  
img
.
TM 5-3805-291-23-1
ELECTRICAL SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0013 00
FUEL FILTER DIFFERENTIAL PRESSURE SWITCH CIRCUIT TEST - CONTINUED
0013 00
427-C0686
427-C0687
427-C0688
Inspect electrical connectors and wiring. Refer to Electrical Connector Inspection (WP 0022 00).
2.
a.
Place battery disconnect switch in OFF position (TM 5-3805-291-10).
b.
Perform 10 lb (45 N) pull test on each wire in ECM connectors associated with ECM power supply.
0013 00-52