TM 5-3805-291-23-1
ELECTRICAL SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0013 00
FUEL FILTER DIFFERENTIAL PRESSURE SWITCH CIRCUIT TEST - CONTINUED
0013 00
427-C0686
427-C0687
427-C0688
Inspect electrical connectors and wiring. Refer to Electrical Connector Inspection (WP 0022 00).
2.
a.
Place battery disconnect switch in OFF position (TM 5-3805-291-10).
b.
Perform 10 lb (45 N) pull test on each wire in ECM connectors associated with ECM power supply.
0013 00-52