TM 5-3805-291-23-1
POWERTRAIN TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0014 00
FILL TIME FOR TRANSMISSION CLUTCH (MSD) CALIBRATION - CONTINUED
N OT E
If new clutch solenoid modulating valve was installed, shift transmission 12 times into speed or direction
that uses clutch solenoid modulating valve. Allow sufficient time for corresponding clutch to be fully pres-
surized.
8.
Click "Next" (23) to start calibration.
9.
Click "Next" (23) to begin next step. Continue this process to complete calibration procedure.
N OT E
Calibration procedure continuesuntil ECM determines that one step does not meet specification.
Middle display area will display message to alert error.
After correcting any problems, calib ation will proceed. After brief initialization, each clutch is
r
calibrated in sequence without any input from user. Middle display area will inform user of
progress of calibration. Calibration of each clutch takes approximately 90 seconds.
10.
Correct error described in middle display area or cancel calibration by clicking "Cancel" (24).
427-C0746
0014 00-34