• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
POSITION SENSOR (LEFT BRAKE PEDAL) (MSD) CALIBRATION - CONTINUED
POSITION SENSOR (LEFT BRAKE PEDAL) (MSD) CALIBRATION - CONTINUED

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  930    931    932    933    934  935  936    937    938    939    940  
img
TM 5-3805-291-23-1
POWERTRAIN TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0014 00
POSITION SENSOR (LEFT BRAKE PEDAL) (MSD) CALIBRATION - CONTINUED
N OT E
Once "Neutralization Setpoint and Pedal Calibraion" has been selected, screen displays incre-
t
mental instructions for calibration.
Top display area displays status pa ameters monitored during calibration.
r
Middle display area displays information about status of calibration.
Bottom display area displays increm ntal instructions for calibration.
e
8.
Click "Next" (23) to start calibration.
9.
Click "Next" (23) to begin next step. Continue this process to complete calibration procedure.
427-C0752
N OT E
ECM detects possible error messages during calib ation. When an error is detected ECM will
r
stop calibration.
Error message will be displayed in middle display area.
0014 00-38