TM 5-3805-291-23-1
HYDRAULIC SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0017 00
MAIN CONTROL VALVE (MSD) CALIBRATION - CONTINUED
Manual Calibration Procedure - Continued
N OT E
MSD screen will be divided into three display areas. Top section of screen will be used to display important
status parameters that are monitored during calibration. Middle section of screen displays information
about calibration procedure. Bottom section of screen displays step-by-step instructions for calibration.
Step that currently needs performing will be in bold text. All other steps will be displayed in gray text.
8.
Click "Next" (7) to begin first calibration. Check mark button will be placed to left of completed step and next step will
be highlighted in bold text. After successful completion of step, you may need to click "Next" to begin the following
step. The following steps listed in bottom section of screen until calibration procedure is complete.