• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 3. Relationship Between Temperature and Pressure (R-134a Refrigerant).
Table 3. Relationship Between Temperature and Pressure (R-134a Refrigerant) - Continued.

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1090    1091    1092    1093    1094  1095  1096    1097    1098    1099    1100  
img
TM 5-3805-291-23-1
AIR CONDITIONING SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0018 00
REFRIGERANT SYSTEM CHARGE - CONTINUED
Relationship Between Temperature and Pressure (R-134a Refrigerant) - Continued
Table 3. Relationship Between Temperature and Pressure (R-134a Refrigerant) - Continued.
Pressure psi(1) (kPa)
Temperature F (C)
38.0F (3C)
33.0 psi (228 kPa)
39.0F (4C)
34.0 psi (234 kPa)
40.0F (4C)
34.9 psi (241 kPa)
41.0F (5C)
35.9 psi (248 kPa)
42.0F (6C)
36.9 psi (254 kPa)
43.0F (6C)
37.9 psi (261 kPa)
44.0F (7C)
38.9 psi (263 kPa)
45.0F (7C)
39.9 psi (275 kPa)
46.0F (8C)
41.0 psi (283 kPa)
47.0F (8C)
42.0 psi (290 kPa)
48.0F (9C)
43.1 psi (297 kPa)
49.0F (9C)
44.2 psi (305 kPa)
50.0F (10C)
45.3 psi (312 kPa)
51.0F (11C)
46.4 psi (320 kPa)
52.0F (11C)
47.5 psi (328 kPa)
53.0F (12C)
48.7 psi (336 kPa)
54.0F (12C)
49.9 psi (344 kPa)
55.0F (13C)
51.0 psi (352 kPa)
56.0F (13C)
52.2 psi (360 kPa)
57.0F (14C)
53.5 psi (369 kPa)
58.0F (14C)
54.7 psi (377 kPa)
59.0F (15C)
55.9 psi (385 kPa)
60.0F (16C)
57.2psi (394 kPa)
61.0F (16C)
58.2 psi (403 kPa)
62.0F (17C)
59.8 psi (412 kPa)
63.0F (17C)
61.1 psi (421 kPa)
64.0F (18C)
62.4 psi (430 kPa)
65.0F (18C)
63.8 psi (440 kPa)
0018 00-16