TM 5-3805-291-23-1
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
INCLUDING LUBRICATION INSTRUCTIONS - CONTINUED
0020 00
Table 1. Unit Preventive Maintenance Checks and Services (PMCS)
Including Lubrication Instructions for the 966H - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL HOURS
PROCEDURE
CAPABLE IF:
b. Use control knob to release hydraulic
Semiannual
Radiator
15
oil cooler. Swing hydraulic oil cooler
(Cont)
(TM 5-3805-291-10).
427-C1503
427-C1503
WARN I N G
Particles blown by compressed air are hazardous. Use a
maximum of 30 psi (207 kPa) when cleaning components.
DO NOT direct compressed air against human skin. Make
sure air stream is directed away from user and other
personnel in the area. To prevent injury, user must wear
protective goggles or face shield. Failure to follow this
warning may result in injury to personnel.
c. Use compressed air to clean radiator Class III leaks are evident.
cooling fins and hydraulic oil cooler.
0020 00-11